TROUBLESHOOTING                                                         CONTENTS        PAGE    1     2     4     LASTPAGE

 

 

 

1. No vibration ?

 

A.  Electrical

a. Check to see if the power is off or controller turned down or off.

b. Check to see if a fuse is blown.

c. Check the connections.

d. Check for broken wires.

e. Check the coil it may be overheated or shorted out.

 

B.  Mechanical

a. Is there a gap between the coil and the striker plate?

b. Is the bowl making contact with other equipment?

c.   Check the springs, generally these break at the edge of the base lug or

     the edge of the cross-arms. Check welds and bolts for breakage.

 

2. Slow, irregular vibration or loud abnormal sound?

 

A.  Electrical

a. Is the input voltage fluctuating?

b. Is there a loose connection?

 

B.  Mechanical

a.  Check all bolts for looseness or breakage, especially bolts holding spring

     packs together.

b. Is everything level?

c. Is the bowl overloaded?

d. Is the bowl making contact with other equipment?

e.  Is the table or plate causing interference vibration? Stands or tables must be

    level, rigid, and of adequate strength to not set up its’ own resistant vibration.

f.     Is the coil gap too close or too far?

g.  Is there excessive dirt or oil in bowl?

h.   Is the base unit improperly tuned?

 